HOBO® H6 Family
Modelo: Familia H6
imagen producto

The HOBO H6 Family of data loggers record on/off or open/closed status changes, storing time, date, and state information for each change.

Family Features & Specifications

  • Operating range: -20° to 70°C (-4° to 158°F), 0 to 95% relative humidity, non-condensing, non-fogging
  • Capacity: 2000 state changes
  • Time resolution: 0.5 second
  • Time accuracy: ±1 minute per week at +20°C (+68°F)
  • Programmable start time/date
  • Readout and relaunch with optional HOBO H9 Shuttle
  • Battery check at launch
  • Blinking LED lights show current state
  • Memory modes: stop when full, wrap-around when full
  • Download full logger in just 90 seconds
  • Nonvolatile EEPROM memory retains data even if battery fails
  • User-replaceable battery lasts one year
  • Mounting kit included (hook/loop, magnet, and tape)
  • Drop-proof to 5 feet
  • Size/Weight: 6.0 x 4.8 x 1.9cm (2.4 x 1.9 x 0.8")/approx. 29 gms (1 oz.)
  • One-year warranty

    HOBO H6 State Data Logger
    Part # H06-001-02

    Monitors when doors are open/closed using an internal magnetic reed switch and external magnet. External input cable included to monitor contact closures of remote devices or presence of positive DC voltage.
    Can be used with AC Current switch to monitor equipment on/off and run-times.

    Key Specifications:
  • Two Inputs: a magnetic sensor mounted in the logger detects when doors are opened and closed (external magnet included). An external input cable detects contact closures.
  • Spacing between HOBO State and external magnet: closed =1/4"; open =3/4"
  • External contact input: passive relay switch or contact closure

    HOBO H6 Light On/Off Data Logger
    Part # H06-002-02

    The light intensity threshold monitored is adjustable from approximately 10 to 100 lumens. The HOBO's light sensitivity is peaked in the forward direction and can be taken advantage of to minimize the effect of other light sources when trying to determine the on/off state of a particular light source.

    Key Specifications:
  • Light threshold adjustment range: approx. 10 to 100 lumens/m2 (fluorescent light). Its sensitivity to incandescent light is about ten times greater.

    HOBO H6 Motor On/Off with AC-Field Sensor Data Logger
    Part #H06-004-02

    Magnetic field intensities fall off rapidly with increasing distance from their source (motor, transformer, or even a single wire carrying a large AC current). This means that the logger must be mounted very close to (ideally directly on) the field source. While this may make it less convenient to attach the logger, it means that interference from other sources is less likely.

    Key Specifications:
  • Magnetic field threshold: 2 G at 60 Hz. The logger will typically work with AC motors drawing 1 amp or more. Mount it on or close to the motor housing or to one phase of the power line to the equipment being monitored.
  • Angular response: the logger is sensitive to the part of the AC field that is perpendicular to the logger's face.
  • Marca: HOBO - Onset
    +54 9 11 6713-8305